Range A · Home Inverter, Solar & Expandable Packs

12.8 V, 25.6 V and 48 V/51.2 V small-to-mid pack specifications. Premium low-voltage modules engineered as safe, long-life options for domestic, inverter and solar environments.

Range A · Home Inverter, Solar & Expandable Packs
ParameterZYN-H100ZYN-H150ZYN-H200 / M100ZYN-S100 / S150 / I160
Electrical performance & capacity
Nominal voltage12.8 V12.8 V12.8 V (H200) / 25.6 V (M100)51.2 V (S100/S150) / 48 V (I160)
Rated capacity100 Ah150 Ah200 Ah (H200) / 100 Ah (M100)100 Ah (S100) / 150 Ah (S150) / 160 Ah (I160)
Energy outputSee verification note 51.2 kWh1.8 kWh2.56 kWh5.0 kWh (S100) / 7.5 kWh (S150) / 7.7 kWh (I160)
Depth of discharge95% usable95% usable95% usable95% usable
Operational charge & discharge profiles
Standard C-rateSee verification note 40.5C continuous0.5C continuous0.5C continuous0.5C (S100/S150) / 1.5C max (I160)
Max charge current50 A75 A100 A (H200) / 50 A (M100)100 A (S100) / 150 A (S150) / 250 A (I160)
Backup window~150 min @ 500 W~225 min @ 500 W~300 min @ 500 W~100–150 min @ 3000 W max
Mechanical & environmental protection
Chemistry baseSee verification note 1Lithium iron phosphate (LFP) across the entire range
Ingress classIP56 indoorIP56 indoorIP56 indoorIP56 indoor (S100/S150) / IP67 (I160)
Thermal topologyPassive natural convection — zero fan-noise acoustics across the entire range
Lifecycle & warranty
Cycle life to 80% SoHSee verification note 36,000 – 8,500 cycles baseline @ 25 °C
Warranty windowSee verification note 25 years onsite from the date of commissioning

Verification notes

  1. 1RESOLVED — ZYN-I160 is LFP. The source specification document listed LTO; that is superseded. The entire range is lithium iron phosphate. Three dependent figures moved with the correction: depth of discharge is 95% (not 100%), and cycle life is 6,000–8,500 (not 20,000+) — both of those were LTO characteristics rather than LFP ones.
  2. 2RESOLVED — 5 years onsite, across the whole ZYNTRA range. The source specification document listed 3 years for six of seven models; that is superseded by the Residential & Commercial Limited Warranty Policy, which is the contractual document. Coverage is tiered: Years 1–2 comprehensive (parts, cells, BMS boards, labour, travel, logistics), Years 3–5 service (labour, diagnostics and freight free; replacement parts at cost).
  3. 3Cycle life is stated here as the full 6,000–8,500 range at 25 °C. Product and Solution pages use “up to 8,000 cycles”, which sits inside that range — the shorter form is the marketing figure, this is the engineering one.
  4. 4ZYN-I160 remains the ruggedised model, but the differentiator is thermal management and enclosure — not a different chemistry. Its 1.5C rate, 250 A charge current and IP67 rating come from an advanced thermal management system and an upgraded enclosure, which is what enables faster charging and harsher outdoor conditions on the same LFP cells.
  5. 5ZYN-H200 energy output computes to 2.56 kWh (12.8 V × 200 Ah), matching ZYN-M100 (25.6 V × 100 Ah). The Residential ESS page rounds H200 to 2.5 kWh.

Range A · Stackable Commercial Cabinet Blocks

High-capacity stackable 51.2 V LFP building blocks designed for centralised energy management, scalability, and matching with commercial building networks or mid-scale enterprise layouts.

Range A · Stackable Commercial Cabinet Blocks
ParameterZYN-IND-10ZYN-IND-50ZYN-IND-100
System configuration & capacity
Nominal system voltage51.2 V
Total capacity allocation200 Ah1,000 Ah equivalent2,000 Ah equivalent
Energy storage baseSee verification note 210.24 kWh51.20 kWh102.40 kWh
System scalabilitySingle modular block5-module stacked array10-module cabinet matrix
Depth of dischargeUp to 95% functional discharge depth with zero cell health penalties
Charge, discharge & operational thresholds
Standard operational C-rate0.5C continuous / 1C max intermittent load tracking
Max continuous current100 A500 A equivalent1,000 A equivalent
System round-trip efficiency> 92% battery pack level efficiency
Structural architecture & lifecycle protection
Battery chemistryLithium iron phosphate (LiFePO₄), heavy prismatic cells
Operational lifecycle6,000 – 8,500 standard cycles before capacity reduction to 80%
Design asset lifespan15 to 20 calendar years, enforced via centralised balancing algorithms
Ingress protectionIP56 enclosure rating — indoor or sheltered electrical rooms
Inter-module managementCentralised active multi-tier smart BMS tracking voltage and cell impedance profiles
Standard factory warrantySee verification note 15 years

Verification notes

  1. 1Which warranty applies to the ZYN-IND series depends on its line assignment — see the note below. As ZYNTRA it falls under the 5-year Residential & Commercial Limited Warranty Policy; as ZYNTRA+ it would be excluded from that policy and set per project. This needs settling, because it is a contractual difference and not a presentational one.
  2. 2RESOLVED on capacity — the C&I BESS page now carries the exact figures (10.24, 51.20 and 102.40 kWh); the model number remains the nominal designation. STILL OPEN on line assignment: this specification places the ZYN-IND series under ZYNTRA Range A, while the C&I BESS page presents them within the ZYNTRA+ line. That is a contractual question, not a presentational one — as ZYNTRA the 5-year policy applies, as ZYNTRA+ it does not.

Range B · ZyntraPOD All-in-One Energy Appliance

An 8.5 kVA pure sine wave inverter, a 10.5 kWh native low-voltage LFP storage array, and intelligent automated control loops in a single unit for residences, apartments and corporate offices.

Range B · ZyntraPOD All-in-One Energy Appliance
ParameterZyntraPOD
System electrical performance
Inverter output capacity8.5 kVA high-efficiency core, pure sine wave output
Integrated battery capacity10.5 kWh baseline array, scalable 5.0 – 11.7 kWh
Battery system voltage51.2 V native low-voltage internal architecture
System round-trip efficiency> 92% system-level AC-to-AC
Transfer switching timeSub-millisecond handover — UPS-grade, zero interruption for server arrays
Fast recharge cycleFull capacity restored within a 2 – 3 hour window
Physical architecture, aesthetics & safety
Enclosure design profileArchitecture-grade warm-white matte casing (#FBF9F6) with slim ink borders (#10181F)
Chassis form factorFlush wall-mount or localised ground configuration — 625 × 675 × 535 mm
Acoustic & cooling topologySolid-state passive internal thermal convection — 100% silent, fan-free
Thermal breakpoint thresholdOlivine crystalline cell chemistry, thermal runaway floor at +270 °C
Cell cycle rating6,000 – 8,500 cycles baseline
System service lifeSee verification note 110 – 12 years of daily use
Smart software orchestration
Energy optimisationIntegrated intelligent EMS tracking automated peak-tariff shaving
Load prioritisationSmart building control layer safeguarding multi-tier critical load groups during grid faults
Telemetry connectivityEncrypted application sync displaying live financials and real-time State-of-Health

Verification notes

  1. 1System service life is 10–12 years, per the ZyntraPOD page. The source specification document stated 15–20 calendar years, which is the figure that applies to the standalone packs on Residential ESS; ZyntraPOD runs as an always-on inverter and battery system rather than backup-only, so it sees far more continuous duty and carries the more conservative rating. The 6,000–8,500 cycle rating is unchanged — it is the cell rating, which the duty cycle then consumes faster.

Before commissioning

Confirm against the installation manual.

Specifications may change without notice as part of continuous engineering improvement. Product performance depends on installation, operating conditions and system configuration. Information published here is not engineering design documentation or a contractual specification — always confirm against the model-specific installation manual before commissioning.